25 TON CHILLERS MADE IN THE USA

25 Ton Water Chillers

Cold Shot Chillers two stage air cooled water chillers are made in the USA and are among the most durable and dependable chillers on the market. We offer 25-Ton chillers in different flow designs.  These are available in stationary air-cooled water chillers and liquid-cooled water chillers that do not include a pump or a tank. This machine is also offered as a portable system which includes a complete system with controls, circulating water pump and holding tank.  Other options include reverse flow and continuous flow.

25 Ton Air-cooled Chiller (Portable)

Two stage “Portable” air cooled water chiller unit features tandem hermetic scroll compressors and R410A refrigerant for effective and reliable cooling. The evaporator for this unit is made of copper-brazed stainless-steel plates and built to last. This unit will provide approximately 300,000 BTU/HR with 50 F leaving chill fluid temperature and 95 F ambient conditions.  The unit weighs approximately 1700 lbs. in total with dimensions of 88” L x 80” W x 61” H.

Standard Features

Controls: This unit comes standard with an electronic programmed temperature controller with constant (set point & process) temperature readout.

Refrigeration Components: Efficient scroll compressors, balanced port expansion valves, sight glass/moisture indicators, pump down valves, filter drier, fan cycling head pressure controls.

Process Fluid Components:  Bronze “Y” strainer with 20 mesh stainless steel screen. Pumps are stainless steel centrifugal. Tanks are insulated with shoe box lid, fill port, and level sight glass. Portable systems will include a bypass flow valve.

Safety Controls: High and low refrigerant pressure, high and low fluid temperature, freeze, low water flow, internal overloads, thermal overload circuit breakers and/or safety fuses for compressors, pumps, and fan motors, temperature relief fusible plug on liquid lines of each circuit.

Construction: Welded steel powder coated frame and full metal cabinet, copper piping connections.

Warranty: One year for parts / five year for the compressor.

25 Ton Air-Cooled Chiller (Stationary)

The two-stage air-cooled “Stationary” water chiller systems from Cold Shot will typically have separate controls for the chiller and the pump(s), with an electrical connection to each component.  The pump and tank are typically separated from the chiller and connected on site.  They are designed for either indoor or outdoor installation.  Each system includes hermetic scroll compressors with R-410A refrigerant.

Standard Features

Electronic programmed temp. controller, efficient scroll compressors, Bronze “Y” strainer with 20 mesh stainless steel screen. High and low refrigerant pressure controls, high and low fluid temperature, low water flow, thermal overloads for compressors, safety fuses or overloads for pump.  Microchannel condenser coil. Welded steel powder coated frame and full metal cabinet, copper piping connections.

Standard Features

Controls: The unit comes standard with an electronic programmed temperature controller with constant (set point & process) temperature readout.

Refrigeration Components: Efficient scroll compressors, balanced port expansion valves, sight glass/moisture indicators, pump down valves, filter drier, fan cycling head pressure controls.

Process Fluid Components: Bronze “Y” strainer with 20 mesh stainless steel screen.

Safety Controls: High and low refrigerant pressure, high and low fluid temperature, low water flow, thermal overloads for compressor and fan motors.

Construction: Welded steel powder coated frame and full metal cabinet, copper piping connections.

Warranty: One year for parts / five year for the compressor

25 Ton Air-Cooled Chiller (Reverse Flow)

Cold Shot reverse flow chillers do not include tanks due to their use of an open loop cooling system. For applications of these portable chillers, an external trough or tank on your site is typically used to gravity feed water into the system’s pump. The pump sends the externally sourced water through the chiller and filter before sending it back to the tank/trough.

Standard Features

Controls: The unit comes standard with an electronic programmed temperature controller with constant (set point & process) temperature readout.

Refrigeration Components: Efficient scroll compressors, balanced port expansion valves, sight glass/moisture indicators, pump down valves, filter drier, fan cycling head pressure controls.

Process Fluid Components: Bronze “Y” strainer with 20 mesh stainless steel screen. Pumps are stainless steel centrifugal.

Safety Controls: High and low refrigerant pressure, high and low fluid temperature, low water flow, thermal overloads for compressor and fan motors, safety fuses or overloads for pump.

Construction: Welded steel powder coated frame and full metal cabinet, copper piping connections.

Warranty: One year for parts / five year for the compressor.

25 Ton Water-cooled Units (Portable)

Cold Shot Chillers 25 Ton model WCWC-300-E water-cooled liquid chiller is designed to bring efficient and reliable cooling to all types of industrial applications. These self-contained water-cooled systems are custom made to fit your cooling needs.  Water-cooled chillers allow the refrigeration system to operate at lower head pressure, making them more efficient. 

Water-cooled chillers use water to cool the refrigerant in the condenser.  This chiller includes and efficient water-cooled liquid condenser, typically stainless-steel plates and copper brazed.  The refrigerant and cooling water from a cooling tower or water source do not come in direct contact with each other, these flow in different pathways.  These units are usually installed indoors.  The 25 Ton portable water-cooled chiller weighs approximately 1,300 lbs. and has dimensions of 98” L x 50” W x 85” H.

Standard Features

Controls: Electronic programmed temp. controller with a constant (set point & process) temperature readout.

Refrigeration Components: Efficient scroll compressors, sight glass/moisture indicators, balanced port expansion valves, filter drier, access ports and or service valves, pressure actuated head pressure controls, liquid receiver.

Process Fluid Components: Bronze “Y” strainer with 20 mesh stainless steel screen. Pumps are stainless steel centrifugal. Tanks are insulated with shoe box lid, fill port, and level sight glass. Portable systems will include a bypass flow valve.

Safety Controls: High and low refrigerant pressure controls, high and low fluid temperature, low water flow, thermal overloads for compressors, safety fuses or overloads for pump.

Construction: Welded steel powder coated frame and full metal cabinet, copper piping connections.

Warranty: One-year parts / five-year compressor.

25 Ton Water-cooled Chillers (Reverse Flow)

The Cold Shot Chillers 25 Ton reverse flow water-cooled water chiller features a PLC controlled with self-diagnostics, WIFI/LAN/LTE connectivity for predictive maintenance.  A 25 Ton model WCWC-300-E-RF water-cooled fluid chiller provides 300,000 BTU/Hr. of cooling capacity with 50°F leaving fluid temperature with 85°F incoming condensing water temperature.

Water-cooled chillers use tower water to circulate through the water cooled condenser.  These units are used in many applications and can provide a constant performance. Liquid cooled chillers range in size and are typically compact and designed to reside indoors protected from outdoor ambient conditions.  While water cooled chillers can operate more efficient, it still requires an additional cooling tower system that will require additional installation and maintenance.

The unit measures 90” L x 50” W x 72” H and weighs approximately 1100 lbs.

Standard Features

Controls: Electronic programmed temperature controller with constant (set point & process) temperature readout.

Refrigeration Components: Efficient scroll compressors, sight glass/moisture indicators, balanced port expansion valves, filter drier, access ports and or service valves, pressure actuated head pressure controls, liquid receiver.

Process Fluid Components: Bronze “Y” strainer with 20 mesh stainless steel screen. Pumps are stainless steel centrifugal. Tanks are insulated with shoe box lid, fill port, and level sight glass. Portable systems will include a bypass flow valve.

Safety Controls: High and low refrigerant pressure, high and low fluid temperature, low water flow, thermal overloads for compressors, safety fuses or overloads for pump.

Construction: Welded steel powder coated frame and full metal cabinet, copper piping connections.

Warranty: One year parts / five year compressor.

25 Ton Chiller Specifications

Model #TypeStyleCapacityVoltagePump HP + Flow RateConnections
ACWC-300-EAir-cooledPortable300,000 BTU/HR*208-230/3/60460/3/607-1/2 HP 160gpm@30psi1 1/4” MNPT IN/ OUT
ACWC-300-E-STAir-cooledStationary300,000 BTU/HR*208-230/3/60460/3/60N/A1 1/4” MNPT IN/ OUT
ACWC-300-E-RFAir-cooledReverse Flow300,000 BTU/HR*208-230/3/60460/3/607-1/2 HP 160gpm@30psi1 1/4” MNPT IN/ OUT
WCWC-300-EWater-cooledPortable300,000 BTU/HR*208-230/3/60460/3/607-1/2 HP 160gpm@30psi1 1/4” MNPT IN/ OUT
WCWC-300-E-STWater-cooledStationary300,000 BTU/HR*208-230/3/60460/3/60N/A1 1/4” MNPT IN/ OUT
WCWC-300-E-RFWater-cooledReverse Flow300,000 BTU/HR*208-230/3/60460/3/607-1/2 HP 160gpm@30psi1 1/4” MNPT IN/ OUT


* Capacity- 50°F LCWT/95°F AMB
** Capacity- 50°F LCWT/85°F CWT

Note: All specifications subject to change without notice. Specify Voltage and Ambient Condition upon ordering.

25 Ton Chiller Price

Pricing starting as low as $14,000.00


Request a Quote

Request a Quote (Footer Form)

Request a Quote

Max. file size: 8 MB.